API 579 FFS Level 1 — General Metal Loss & LTA

Fitness-For-Service Screening per API 579-1 / ASME FFS-1 Parts 4 & 5

Level 1 FFS screening for corroded pressure equipment. Implements Part 4 (General Metal Loss) and Part 5 (Local Thin Area) of API 579-1/ASME FFS-1 for cylindrical shells under internal pressure. If Level 1 passes, the equipment is fit for continued service at MAWP. If Level 1 fails, escalate to Level 2.

Equipment

in
in
psig
psi
SA-516 Gr 70 @ ≤100°F = 17,500

Inspection Data

in
Thinnest point in CML / inspection area
in
Arithmetic average over CML
in
Corrosion rate × interval to next inspection
in
To nearest nozzle / weld / head

Local Thin Area (Part 5)

in
Longitudinal extent of thin region
in
in
Sound metal away from LTA

Key Equations

Required wall thickness (ASME VIII UG-27):

tmin = P · R / (S · E − 0.6 · P)

Future wall available:

tfuture = tmm − FCA

General-loss acceptance (Part 4):

tam − FCA ≥ tmin AND tmm − FCA ≥ max(0.5·tnom, 0.1·tnom + 0.1 in)

LTA shell parameter (Part 5):

λ = 1.285 · s / √(D · tmin)

Remaining Strength Factor:

RSF = (tmm − FCA) / tmin [acceptable RSF ≥ 0.9]

Reduced MAWP if RSF < RSFallow:

MAWPr = MAWP · (RSF / RSFallow)