Hydrate Inhibition (MeOH / MEG) Calculator

Hammerschmidt 1934 — required wt % & injection rate

Compute the minimum mass fraction of methanol, MEG, DEG, or TEG required in free water to suppress hydrate formation by a target ΔT, and the resulting injection rate. Per Hammerschmidt (1934) and GPSA §20. Pairs with Hydrate Prediction — predict where the hydrate envelope sits, then size the inhibitor injection to stay clear.

Inhibitor & Target

°F
wt %

Free Water & Gas

lb/hr
MMscfd
lb/MMscf

Economics

$/gal

Equations

Hammerschmidt (1934):

ΔT (°F) = KH · W / (MW · (100 − W))

Inverted for W:

W (wt %) = 100 · ΔT · MW / (KH + ΔT · MW)

Mass balance:

minhib = W · mwater / (Clean − W)