Mesh Demister Pad Sizing

Equipment design · Mist eliminator · Otto York / GPSA §7

Mesh Mist-Eliminator Pad
Souders-Brown design face velocity, pad area, % of design, pressure drop and droplet cutoff for a mesh demister. Per Otto York / GPSA §7.

Vessel & Gas

m
m³/s
kg/m³
kg/m³

Pad

ft/s
in
psig

Engineering Basis

  • Vdesign = K·√((ρl−ρv)/ρv); K (York ~0.35 ft/s) derated for pressure.
  • Face velocity = Qgas/((π/4)D²); design 75-100% (>100% re-entrains).
  • ΔP ∝ (V/Vdesign)² × thickness; standard mesh removes ≳3-5 µm.
  • Standards: Otto York Mist Eliminator, GPSA EDB §7, Souders-Brown.