Reboiler Sizing Calculator

TEMA / API 660 / GPSA Ch. 8

Reboiler Sizing Calculator
Sizes kettle, thermosiphon, and forced-circulation reboilers. Calculates heat duty, LMTD, required heat transfer area, tube bundle geometry, and critical heat flux per TEMA 10th Ed., API 660, and GPSA Ch. 8.
TEMA 10th Ed. API 660 GPSA Ch. 8
Reboiler Type:
Kettle: Shell-side boiling with enlarged shell. Best for clean fluids, moderate duties, and amine/glycol regeneration.

Process Fluid

Auto-fills latent heat and density for common fluids
GPM
°F
psig
%
Percent of feed vaporized (typical 15-35%)
BTU/lb
Enter 0 for auto-calculation from fluid type
lb/ft³
Enter 0 for auto-calculation from fluid type

Heating Medium

psig
Condensing steam temperature derived from pressure

Design Parameters

inches
ft
Standard: 8, 10, 12, 16, 20 ft
inches
Typically 1.25 × tube OD minimum
Triangular: higher tube count. Square: easier cleaning.
hr·ft²·°F/BTU
TEMA: 0.001 (clean) to 0.005 (fouling service)
Oversurface factor (1.10–1.25 typical)

Known Duty (Optional)

MMBTU/hr
If provided, skips duty calculation and sizes bundle directly

Typical Overall U Values (BTU/hr·ft²·°F)

Service Kettle Thermosiphon
Amine regenerator100–150120–180
Glycol regenerator80–120100–150
Hydrocarbon (light)100–200150–250
Hydrocarbon (heavy)40–8060–100
Water (steam heated)200–400250–500

Engineering Basis

Heat Transfer Equation:

Q = U × A × LMTD

Where Q = duty (BTU/hr), U = overall coefficient (BTU/hr·ft²·°F), A = area (ft²), LMTD = log mean temperature difference (°F)

Heat Duty (from process):

Q = ṁ × x × λ + ṁ × Cp × ΔT

Latent heat + sensible heat. x = vapor fraction, λ = latent heat, Cp = specific heat.

Critical Heat Flux (Kern):

qmax = 12,000 BTU/hr·ft² (kettle, per GPSA)

LMTD for Condensing Steam: When using condensing steam, the hot-side temperature is constant (saturation temperature at steam pressure). LMTD simplifies to Tsteam − Tboil.

Design Margin: TEMA recommends 10–25% oversurface to account for fouling, uncertainties, and turndown requirements.

Design Guidelines

Kettle Reboiler: Shell diameter typically 1.5–2.0× bundle diameter. Liquid level must cover tube bundle. Max heat flux ~12,000 BTU/hr·ft² per GPSA.
Thermosiphon: Requires sufficient static head (4–15 ft) for natural circulation. Vapor fraction at outlet ≤ 25–35% to avoid dryout.
Forced Circulation: Use when fouling is severe or static head is insufficient. Pump provides circulation independent of boiling.