Post-Combustion Amine Capture Energy

CCUS · MEA / MDEA / Piperazine · Regen energy & OPEX

Post-Combustion Amine CO₂ Capture
Regeneration energy, steam consumption, solvent circulation, and OPEX for amine-based post-combustion CO₂ capture. Solvents: MEA (3.6 GJ/t), MDEA-PZ blend (3.0), piperazine (2.6), CESAR1 (2.4), KS-21 (2.4), advanced (2.4). Per DOE NETL Cost & Performance Baseline.

Flue Gas

kmol/h
mol%
%
°C
bara

Solvent System

mol/mol
mol/mol
bara

Utilities Pricing

$/MWh
$/t

Engineering Basis

  • Solvent baselines: MEA 3.6 GJ/t (commercial reference), MDEA-PZ 3.0, piperazine 2.6, CESAR1 2.4, KS-21 2.4, advanced 2.4.
  • Steam latent at 4 bara saturated: 2133 kJ/kg.
  • Auxiliary power 0.165 MWh/tCO₂: CO₂ compression (~0.105) + solvent pumps + blower + cooling.
  • Solvent circulation: kmol/h_amine = CO₂ captured / (rich − lean loading).
  • Standards: DOE NETL Cost & Performance Baseline (2022), IEAGHG, Rochelle 2009 (Science).