โš—๏ธ

Post-Combustion Amine Capture Energy

CCUS ยท MEA / MDEA / Piperazine ยท Regen energy & OPEX

Post-Combustion Amine COโ‚‚ Capture
Regeneration energy, steam consumption, solvent circulation, and OPEX for amine-based post-combustion COโ‚‚ capture. Solvents: MEA (3.7 GJ/t), MDEA (4.2), MDEA-PZ blend (3.0), piperazine (2.5), advanced (2.2). Per DOE NETL Cost & Performance Baseline.

Flue Gas

kmol/h
mol%
%
ยฐC
bara

Solvent System

mol/mol
mol/mol
bara

Utilities Pricing

$/MWh
$/t

Engineering Basis

  • Solvent baselines: MEA 3.7 GJ/t (commercial reference), MDEA 4.2, MDEA-PZ 3.0, piperazine 2.5, advanced 2.2.
  • Steam latent at 4 bara saturated: 2133 kJ/kg.
  • Auxiliary power 0.45 MWh/tCOโ‚‚: COโ‚‚ compression (~0.35) + solvent pumps + blower.
  • Solvent circulation: kmol/h_amine = COโ‚‚ captured / (rich โˆ’ lean loading).
  • Standards: DOE NETL Cost & Performance Baseline (2022), IEAGHG, Rochelle 2009 (Science).