1. Overview & Tank Types
Storage tank volume calculations are critical for inventory management, custody transfer, and operational planning in the oil and gas industry. Accurate volume determination depends on tank geometry, liquid level measurement, and temperature corrections.
Cylindrical tanks
Vertical & horizontal
Crude oil, refined products, water storage; atmospheric pressure.
Spherical tanks
Pressurized storage
LPG, NGL, refrigerated products; 200-250 psig design pressure.
Rectangular tanks
Process equipment
Clarifiers, wash tanks, skimmer tanks; simple geometry calculations.
API standards
MPMS Chapter 2
Manual of Petroleum Measurement Standards for tank calibration.
Tank Classification by Geometry
| Tank Type | Typical Size | Application | Calculation Method |
|---|---|---|---|
| Vertical cylindrical (flat bottom) | 10,000–500,000 bbl | Crude oil storage | API 2550 strapping |
| Vertical cylindrical (cone roof) | 5,000–80,000 bbl | Refined products | Cylindrical + cone volume |
| Horizontal cylindrical | 50–5,000 bbl | Production batteries | Segment integration |
| Spherical | 500–50,000 bbl | LPG, propane, butane | Spherical cap formulas |
| Spheroid (Hortonsphere) | 2,000–25,000 bbl | Pressurized NGL | Ellipsoidal geometry |
| Rectangular | Variable | Process tanks, clarifiers | L × W × H |
Key Terminology
- Gross capacity: Total geometric volume from tank bottom to highest safe fill level
- Working capacity: Usable volume between minimum operating level and maximum safe fill
- Deadwood: Internal structures (pipes, columns) that displace liquid volume
- Freeboard: Distance from maximum liquid level to tank top (typically 6–12 inches)
- Strapping table: Volume-versus-height calibration table per API 2550
- Innage: Liquid height measured from tank bottom (also called ullage from top)
2. Cylindrical Tank Volumes
Cylindrical tanks are the most common storage configuration in the petroleum industry due to structural efficiency and ease of fabrication.
Vertical Cylindrical Tank (Full Volume)
Vertical Tank with Cone Roof
Horizontal Cylindrical Tank
Horizontal tanks require integration of circular segments. The volume at height h is:
Tank Volume at Partial Fill
| Fill % (by height) | Volume % (vertical) | Volume % (horizontal) | Application |
|---|---|---|---|
| 10% | 10% | 6.5% | Low-level alarm setting |
| 25% | 25% | 17.8% | Minimum operating level |
| 50% | 50% | 50% | Half-full reference |
| 75% | 75% | 82.2% | Normal operating level |
| 90% | 90% | 93.5% | High-level alarm |
Example Calculation: Vertical Tank
Calculate volume in a 40-ft diameter, 30-ft tall vertical tank filled to 25 ft:
Tank Head Volumes (per ASME Section VIII)
Horizontal cylindrical tanks and pressure vessels typically have formed heads on each end. The head type affects total volume:
| Head Type | Volume Factor | Depth | Typical Application |
|---|---|---|---|
| Hemispherical | 0.2618 D³ | D/2 | High pressure vessels (>300 psi) |
| 2:1 Elliptical | 0.1309 D³ | D/4 | Standard ASME pressure vessels |
| Torispherical (F&D) | 0.0847 D³ | 0.169 D | Low pressure, atmospheric tanks |
| Flat | 0 | 0 | Atmospheric storage, rectangular |
Deadwood and Bottom Corrections
- Tank bottom irregularities: Measured during strapping survey; typical correction ±0.1–0.5%
- Internal floating roof: Subtract pontoon volume and support leg displacement
- Heating coils: Subtract pipe volume (typically 0.5–2% of tank volume)
- Structural columns: Wide-column tanks subtract W-beam volume
- Bottom slope: Conical bottoms for drainage add/subtract volume at low levels
3. Spherical Tank Volumes
Spherical tanks provide the strongest geometry for pressurized storage with minimum surface area per unit volume, making them ideal for LPG and NGL storage.
Full Sphere Volume
Spherical Cap (Partial Fill)
Spheroid (Hortonsphere) Volume
Hortonspheres are flattened spheres with ellipsoidal geometry, providing lower profile than full spheres:
Sphere Volume vs. Height Table
| Height (% of D) | Volume (% of total) | Application | Liquid Level |
|---|---|---|---|
| 5% | 0.7% | Low-level alarm | Bottom residual |
| 10% | 2.7% | Emergency reserve | Pump NPSH minimum |
| 25% | 14.6% | Low operating level | Below mid-point |
| 50% | 50.0% | Half-full (equator) | Hemisphere |
| 75% | 85.4% | Normal operating level | Above mid-point |
| 90% | 97.3% | High-level alarm | Near maximum |
| 95% | 99.3% | Maximum safe fill | Vapor space reserve |
Example: Propane Storage Sphere
Pressure-Volume-Temperature Corrections
- Liquid expansion: LPG volume increases ~0.15% per 10°F temperature rise
- Vapor pressure: Propane at 100°F = 215 psia; affects working capacity
- Maximum fill: Typically 85-90% liquid volume at maximum design temperature
- Vapor space: Required for pressure relief and thermal expansion
- Density corrections: Propane SG = 0.507 at 60°F; varies with temperature
4. API 2550 Strapping Tables
API Manual of Petroleum Measurement Standards (MPMS) Chapter 2.2A defines procedures for calibrating vertical cylindrical tanks by measuring external dimensions and calculating volume tables.
Strapping Survey Methods
Strapping Table Format
A strapping table (capacity table) lists volume at incremental liquid heights:
| Gauge Height (ft-in) | Volume (bbl) | Volume (gal) | Incremental (bbl) |
|---|---|---|---|
| 0-0 | 0 | 0 | — |
| 0-3 (3 inches) | 142 | 5,964 | 142 |
| 0-6 (6 inches) | 284 | 11,928 | 142 |
| 1-0 (1 foot) | 568 | 23,856 | 142 |
| 5-0 | 2,840 | 119,280 | 142 |
| 10-0 | 5,680 | 238,560 | 142 |
| 20-0 | 11,360 | 477,120 | 142 |
| 30-0 | 17,040 | 715,680 | 142 |
Example for 40-ft diameter vertical tank, incremental = 142 bbl/ft of height
Temperature Corrections (API MPMS Chapter 11.1)
Temperature corrections are essential for custody transfer measurements. There are two separate corrections:
Deadwood Survey
Internal structures that displace liquid volume must be measured and subtracted:
- Fixed roof support columns: Measure diameter and height of each column; V = πD²H/4
- Heating coils: Measure pipe diameter, total length; V = πd²L/4
- Ladders and platforms: Typically negligible (<0.1%)
- Mixers and agitators: Measure impeller and shaft volume
- Dip tubes and thermowells: Usually ignored unless large diameter
Strapping Certificate
API 2550 requires documentation including:
- Tank identification and location
- Date of calibration and ambient temperature
- Tank dimensions: diameter(s), height, shell plate thicknesses
- Reference gauge point location and datum
- Bottom calibration (if irregular)
- Deadwood schedule
- Complete capacity table at standard temperature
- Surveyor certification and signature
- Recommended recalibration interval (typically 10 years)
5. Capacity & Measurement
Working Capacity vs. Gross Capacity
Level Measurement Methods
| Method | Accuracy | Application | Advantages |
|---|---|---|---|
| Manual gauge tape | ±1/8 inch | API custody transfer | Simple, reliable, no power required |
| Float & tape gauge | ±1/4 inch | Local indication | Continuous reading, mechanical |
| Servo gauge (ATG) | ±1 mm | Automated tank gauging | Remote reading, data logging |
| Radar level (non-contact) | ±2-5 mm | Floating roof tanks | No moving parts, no calibration |
| Hydrostatic pressure | ±0.5% span | Pressurized tanks | Simple, works in agitated tanks |
| Ultrasonic | ±3-10 mm | Process tanks | Low cost, easy installation |
Gauge Reference Point
Temperature Measurement
Accurate temperature measurement is critical for volume corrections:
- Manual thermometer: API gravity thermometer, ±0.5°F accuracy
- Spot temperature: Single measurement at mid-height; adequate for small tanks
- Average temperature: Multiple measurements at top, middle, bottom; average per API 7.2
- Automated systems: Thermowell with RTD or thermocouple; continuous monitoring
- Stratification: Temperature can vary 10-20°F from top to bottom in large crude tanks
Density and Mass Calculation
Inventory Management Applications
- Custody transfer: Opening/closing gauges with witness for delivery verification
- Loss control: Daily inventory balance to detect leaks or measurement errors
- Blending: Calculate component volumes for product specification blending
- Scheduling: Determine available capacity for incoming shipments
- Financial reporting: Accurate inventory valuation for accounting
Common Measurement Errors
- Water bottom: Free water accumulation at tank bottom; must be measured separately
- Foam and emulsion: Creates false high level reading; wait for settling
- Roof leg displacement: Floating roof legs displace volume; requires correction table
- Shell distortion: Temperature-induced expansion or structural deformation changes calibration
- Gauge point error: Damaged or moved reference point invalidates strapping table
- Tape stretch: Steel tapes elongate with age and use; verify against master gauge
Ready to use the calculator?
→ Launch Calculator