Internal Flow Area per ASME B31.8 & B36.10M
Wall Thickness Tolerance:
±12.5% per API 5L / ASTM A530
Ovality (API 5L Table 10):
1.0% (<8.625" OD), 1.5% (≥12.75")
Thermal Expansion (C-Steel):
6.5×10⁻⁶ /°F (ASME B31.1)
Understand pipe flow area principles, calculations, and industry applications
Nominal Inside Diameter (ID):
Flow Area:
Thermal Expansion Adjustment:
1. Nominal Flow Area
Uses specified OD and wall thickness per ASME B36.10M. Includes thermal expansion at operating temperature. Use for design-basis calculations.
2. Effective Flow Area
Accounts for corrosion allowance (thicker effective wall = smaller ID) and pipe ovality per API 5L Table 10. Represents design flow area for service life calculations.
3. Maximum Flow Area
Uses minimum wall thickness (nominal -12.5% per API 5L tolerance) giving maximum ID. Use for conservative pressure drop calculations where larger area = lower velocity = less conservative.