Separator Sizing Calculator

Per API 12J with Souders-Brown Methodology

Advertisement
Gas-Liquid Separator Sizing Calculator
Sizes two-phase and three-phase separators using Souders-Brown equation and retention time criteria. Calculates vessel dimensions, demister sizing, and internals per API 12J and GPSA standards.

Flow Rates & Conditions

Gas flow at standard conditions (60°F, 14.7 psia)
Oil/condensate flow rate
same
Produced water (same units as oil)
psig
°F

Fluid Properties

lb/ft³
At operating conditions
cP
At operating temperature
lb/ft³
At operating conditions
cP
At operating temperature
lb/ft³
Typically 62.4 lb/ft³
μm
100-200 microns typical

Design Parameters

Affects K-factor for gas capacity
-
3-5 typical for horizontal
min
API 12J: 1-3 min for oil
-
1.15-1.25 for flow variations
in
4-6" for mesh pads

Design Formulas (API 12J)

Souders-Brown Equation:

Vt = K × √[(ρL - ρG) / ρG]

Stokes Law (Droplet Settling):

Vd = 1.78×10⁻⁶ × dp² × Δρ / μ

Horizontal Liquid Volume:

V = 0.3927 × D² × L (at 50% level)

Shell Thickness (ASME VIII):

t = PR / (SE - 0.6P) + CA

K-factor: Mesh Pad (0.12-0.18), Vane Pack (0.27-0.35)
All calculations per API 12J, API RP 14E, ASME Section VIII

Advertisement